Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
BMC Pediatr ; 24(1): 315, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38714956

RESUMO

BACKGROUND: Ultrasound (US) is often the first method used to look for brain or cerebrospinal fluid (CSF) space pathologies. Knowledge of normal CSF width values is essential. Most of the available US normative values were established over 20 years ago, were obtained with older equipment, and cover only part of the age spectrum that can be examined by cranial US. This prospective study aimed to determine the normative values of the widths of the subarachnoid and internal CSF spaces (craniocortical, minimal and maximal interhemispheric, interventricular, and frontal horn) for high-resolution linear US probes in neurologically healthy infants and children aged 0-19 months and assess whether subdural fluid collections can be delineated. METHODS: Two radiologists measured the width of the CSF spaces with a conventional linear probe and an ultralight hockey-stick probe in neurologically healthy children not referred for cranial or spinal US. RESULTS: This study included 359 neurologically healthy children (nboys = 178, 49.6%; ngirls = 181, 50.4%) with a median age of 46.0 days and a range of 1-599 days. We constructed prediction plots, including the 5th, 50th, and 95th percentiles, and an interactive spreadsheet to calculate normative values for individual patients. The measurements of the two probes and the left and right sides did not differ, eliminating the need for separate normative values. No subdural fluid collection was detected. CONCLUSION: Normative values for the widths of the subarachnoid space and the internal CSF spaces are useful for evaluating intracranial pathology, especially when determining whether an increase in the subarachnoid space width is abnormal.


Assuntos
Espaço Subaracnóideo , Ultrassonografia , Humanos , Lactente , Estudos Prospectivos , Masculino , Feminino , Valores de Referência , Recém-Nascido , Ultrassonografia/métodos , Espaço Subaracnóideo/diagnóstico por imagem , Líquido Cefalorraquidiano/diagnóstico por imagem
2.
Eur Radiol ; 34(3): 1716-1723, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37644149

RESUMO

OBJECTIVES: To introduce an automated computational algorithm that estimates the global noise level across the whole imaging volume of PET datasets. METHODS: [18F]FDG PET images of 38 patients were reconstructed with simulated decreasing acquisition times (15-120 s) resulting in increasing noise levels, and with block sequential regularized expectation maximization with beta values of 450 and 600 (Q.Clear 450 and 600). One reader performed manual volume-of-interest (VOI) based noise measurements in liver and lung parenchyma and two readers graded subjective image quality as sufficient or insufficient. An automated computational noise measurement algorithm was developed and deployed on the whole imaging volume of each reconstruction, delivering a single value representing the global image noise (Global Noise Index, GNI). Manual noise measurement values and subjective image quality gradings were compared with the GNI. RESULTS: Irrespective of the absolute noise values, there was no significant difference between the GNI and manual liver measurements in terms of the distribution of noise values (p = 0.84 for Q.Clear 450, and p = 0.51 for Q.Clear 600). The GNI showed a fair to moderately strong correlation with manual noise measurements in liver parenchyma (r = 0.6 in Q.Clear 450, r = 0.54 in Q.Clear 600, all p < 0.001), and a fair correlation with manual noise measurements in lung parenchyma (r = 0.52 in Q.Clear 450, r = 0.33 in Q.Clear 600, all p < 0.001). Classification performance of the GNI for subjective image quality was AUC 0.898 for Q.Clear 450 and 0.919 for Q.Clear 600. CONCLUSION: An algorithm provides an accurate and meaningful estimation of the global noise level encountered in clinical PET imaging datasets. CLINICAL RELEVANCE STATEMENT: An automated computational approach that measures the global noise level of PET imaging datasets may facilitate quality standardization and benchmarking of clinical PET imaging within and across institutions. KEY POINTS: • Noise is an important quantitative marker that strongly impacts image quality of PET images. • An automated computational noise measurement algorithm provides an accurate and meaningful estimation of the global noise level encountered in clinical PET imaging datasets. • An automated computational approach that measures the global noise level of PET imaging datasets may facilitate quality standardization and benchmarking as well as protocol harmonization.


Assuntos
Processamento de Imagem Assistida por Computador , Tomografia por Emissão de Pósitrons , Humanos , Processamento de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons/métodos , Fluordesoxiglucose F18 , Fígado/diagnóstico por imagem , Algoritmos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Imagens de Fantasmas
3.
Eur Radiol ; 34(3): 1556-1566, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37658140

RESUMO

OBJECTIVE: Bioabsorbable magnesium-based alloy screws release gas upon resorption. The resulting findings in the adjacent soft tissues and joints may mimic infection. The aim of the study was to evaluate the ultrasound (US) findings in soft tissues and joints during screw resorption. METHODS: Prospectively acquired US studies from pediatric patients treated with magnesium screws were evaluated for screw head visibility, posterior acoustic shadowing, twinkling artifact, foreign body granuloma, gas (soft tissue, intra-articular), alterations of the skin and subcutaneous fat, perifascial fluid, localized fluid collections, hypervascularization, and joint effusion. RESULTS: Sixty-six US studies of 28 pediatric patients (nfemale = 9, nmale = 19) were included. The mean age of the patients at the time of surgery was 10.84 years; the mean time between surgery and ultrasound was 128.3 days (range = 6-468 days). The screw head and posterior acoustic shadowing were visible in 100% of the studies, twinkling artifact in 6.1%, foreign body granuloma in 92.4%, gas locules in soft tissue in 100% and intra-articular in 18.2%, hyperechogenicity of the subcutaneous fat in 90.9%, cobblestoning of the subcutaneous fat in 24.2%, loss of normal differentiation between the epidermis/dermis and the subcutaneous fat in 57.6%, localized fluid collection in 9.9%, perifascial fluid in 12.1%, hypervascularization in 27.3%, and joint effusion in 18.2%. CONCLUSION: US findings in pediatric patients treated with magnesium screws strongly resemble infection, but are normal findings in the setting of screw resorption. CLINICAL RELEVANCE STATEMENT: Bioabsorbable magnesium-based alloy screws release gas during resorption. The resulting US findings in the adjacent soft tissues and joints in pediatric patients may mimic infection, but are normal findings. KEY POINTS: • Bioabsorbable magnesium-based alloy screws release gas upon resorption. • The resulting ultrasound findings in children's soft tissues and joints closely resemble those of soft tissue infection or osteosynthesis-associated infection. • Be familiar with these ultrasound findings in order to avoid inadvertently misdiagnosing a soft tissue infection or osteosynthesis-associated infection.


Assuntos
Fraturas Ósseas , Granuloma de Corpo Estranho , Infecções dos Tecidos Moles , Humanos , Masculino , Feminino , Criança , Magnésio , Implantes Absorvíveis , Granuloma de Corpo Estranho/etiologia , Infecções dos Tecidos Moles/etiologia , Fraturas Ósseas/etiologia , Ligas , Fixação Interna de Fraturas/métodos , Parafusos Ósseos/efeitos adversos
4.
Eur Radiol ; 2023 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-38148406

RESUMO

OBJECTIVES: The purpose of this meta-analysis was to determine the diagnostic performance of conventional MRI and MR arthrography for tendinosis, and partial and complete tears of the long head of the biceps tendon (LHBT) using arthroscopy as the reference standard. MATERIALS AND METHODS: A systematic review was performed using predefined data fields in PubMed, and all articles published from January 2000 up to April 2022 were retrospectively pooled and reviewed. Six MRI studies on complete tear (n = 555) and ten studies on partial tear/tendinosis (n = 2487) were included in the analysis. Two of the included studies in each group investigated the use of MR arthrography. The data sets were analyzed using a univariate approach with the DerSimonian and Laird random effects model and the proportional hazards model. RESULTS: MRI shows high specificities in diagnosing complete tears of the LHBT ranging from 93.0 to 99.0%. Diagnostic sensitivity was more heterogeneous ranging from 55.9 to 90.0%. The overall negative likelihood ratio was 0.29 (95% CI: 0.17-0.50) and the overall positive likelihood ratio was 37.3 (95% CI: 11.9-117.4). The mean sensitivity in diagnosing partial tear/tendinosis of the LHBT was 67.8% (95% CI: 54.3-78.9%) and the specificity was 75.9% (95% CI: 63.6-85.0%), resulting in a balanced accuracy of 71.9%. The overall negative likelihood ratio was 0.44 (95% CI: 0.32-0.59) and the overall positive likelihood ratio was 2.64 (95% CI: 1.91-3.65). CONCLUSION: MRI is highly specific for the diagnosis of complete tears of the LHBT, whereas diagnostic sensitivity was more heterogeneous. The diagnosis of partial tears and/or tendinosis of the LHBT remains challenging on MRI, which may warrant complementary clinical examination or other imaging modalities to increase diagnostic confidence in equivocal cases. CLINICAL RELEVANCE STATEMENT: Conventional MRI and MR arthrography have high diagnostic performance for complete tendon tear when compared to arthroscopy. The diagnosis of tendinosis/partial tears remains challenging and may require comparison with clinical tests and other imaging modalities. KEY POINTS: •There is no clear consensus regarding the primary imaging modality for the evaluation of LHBT disorders. •Conventional MRI and MR arthrography are highly specific in diagnosing complete tears of the LHBT. •Diagnosis of partial tears/tendinosis of the LHBT on conventional MRI and MR arthrography remains a diagnostic challenge.

5.
Eur Radiol ; 2023 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-37855853

RESUMO

OBJECTIVES: To assess the evolution of administered radiotracer activity for F-18-fluorodeoxyglucose (18F-FDG) PET/CT or PET/MR in pediatric patients (0-16 years) between years 2000 and 2021. METHODS: Pediatric patients (≤ 16 years) referred for 18F-FDG PET/CT or PET/MR imaging of the body during 2000 and 2021 were retrospectively included. The amount of administered radiotracer activity in megabecquerel (MBq) was recorded, and signal-to-noise ratio (SNR) was measured in the right liver lobe with a 4 cm3 volume of interest as an indicator for objective image quality. Descriptive statistics were computed. RESULTS: Two hundred forty-three children and adolescents underwent a total of 466 examinations. The median injected 18F-FDG activity in MBq decreased significantly from 296 MBq in 2000-2005 to 100 MBq in 2016-2021 (p < 0.001), equaling approximately one-third of the initial amount. The median SNR ratio was stable during all years with 11.7 (interquartile range [IQR] 10.7-12.9, p = 0.133). CONCLUSIONS: Children have benefited from a massive reduction in the administered 18F-FDG dose over the past 20 years without compromising objective image quality. CLINICAL RELEVANCE STATEMENT: Radiotracer dose was reduced considerably over the past two decades of pediatric F-18-fluorodeoxyglucose PET/CT and PET/MR imaging highlighting the success of technical innovations in pediatric PET imaging. KEY POINTS: • The evolution of administered radiotracer activity for F-18-fluorodeoxyglucose (18F-FDG) PET/CT or PET/MR in pediatric patients (0-16 years) between 2000 and 2021 was assessed. • The injected tracer activity decreased by 66% during the study period from 296 megabecquerel (MBq) to 100 MBq (p < 0.001). • The continuous implementation of technical innovations in pediatric hybrid 18F-FDG PET has led to a steady decrease in the amount of applied radiotracer, which is particularly beneficial for children who are more sensitive to radiation.

6.
Sci Rep ; 13(1): 18357, 2023 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-37884535

RESUMO

This study aimed to evaluate the diagnostic accuracy of Node Reporting and Data System (Node-RADS) in discriminating between normal, reactive, and metastatic axillary LNs in patients with melanoma who underwent SARS-CoV-2 vaccination. Patients with proven melanoma who underwent a 2-[18F]-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography (2-[18F]-FDG PET/CT) between February and April 2021 were included in this retrospective study. Primary melanoma site, vaccination status, injection site, and 2-[18F]-FDG PET/CT were used to classify axillary LNs into normal, inflammatory, and metastatic (combined classification). An adapted Node-RADS classification (A-Node-RADS) was generated based on LN anatomical characteristics on low-dose CT images and compared to the combined classification. 108 patients were included in the study (54 vaccinated). HALNs were detected in 42 patients (32.8%), of whom 97.6% were vaccinated. 172 LNs were classified as normal, 30 as inflammatory, and 14 as metastatic using the combined classification. 152, 22, 29, 12, and 1 LNs were classified A-Node-RADS 1, 2, 3, 4, and 5, respectively. Hence, 174, 29, and 13 LNs were deemed benign, equivocal, and metastatic. The concordance between the classifications was very good (Cohen's k: 0.91, CI 0.86-0.95; p-value < 0.0001). A-Node-RADS can assist the classification of axillary LNs in melanoma patients who underwent 2-[18F]-FDG PET/CT and SARS-CoV-2 vaccination.


Assuntos
COVID-19 , Melanoma , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Vacinas contra COVID-19 , SARS-CoV-2 , Fluordesoxiglucose F18 , Estudos Retrospectivos , Estadiamento de Neoplasias , Metástase Linfática/patologia , COVID-19/diagnóstico por imagem , COVID-19/patologia , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Melanoma/diagnóstico por imagem , Melanoma/patologia , Vacinação , Compostos Radiofarmacêuticos
7.
Br J Radiol ; 96(1152): 20220482, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37751216

RESUMO

OBJECTIVES: To evaluate the evolution of CT radiation dose in pediatric patients undergoing hybrid 2-[18F]fluoro-2-deoxy-D-glucose (2-[18F]FDG) PET/CT between 2007 and 2021. METHODS AND MATERIALS: Data from all pediatric patients aged 0-18 years who underwent hybrid 2-[18F]FDG PET/CT of the body between January 2007 and May 2021 were reviewed. Demographic and imaging parameters were collected. A board-certified radiologist reviewed all CT scans and measured image noise in the brain, liver, and adductor muscles. RESULTS: 294 scans from 167 children (72 females (43%); median age: 14 (IQR 10-15) years; BMI: median 17.5 (IQR 15-20.4) kg/m2) were included. CT dose index-volume (CTDIvol) and dose length product (DLP) both decreased significantly from 2007 to 2021 (both p < 0.001, Spearman's rho coefficients -0.46 and -0.35, respectively). Specifically, from 2007 to 2009 to 2019-2021 CTDIvol and DLP decreased from 2.94 (2.14-2.99) mGy and 309 (230-371) mGy*cm, respectively, to 0.855 (0.568-1.11) mGy and 108 (65.6-207) mGy*cm, respectively. From 2007 to 2021, image noise in the brain and liver remained constant (p = 0.26 and p = 0.06), while it decreased in the adductor muscles (p = 0.007). Peak tube voltage selection (in kilovolt, kV) of CT scans shifted from high kV imaging (140 or 120kVp) to low kV imaging (100 or 80kVp) (p < 0.001) from 2007 to 2021. CONCLUSION: CT radiation dose in pediatric patients undergoing hybrid 2-[18F]FDG PET/CT has decreased in recent years equaling approximately one-third of the initial amount. ADVANCES IN KNOWLEDGE: Over the past 15 years, CT radiation dose decreased considerably in pediatric patients undergoing hybrid imaging, while objective image quality may not have been compromised.


Assuntos
Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Feminino , Humanos , Criança , Adolescente , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Encéfalo
8.
Sci Rep ; 13(1): 11332, 2023 07 13.
Artigo em Inglês | MEDLINE | ID: mdl-37443158

RESUMO

To evaluate whether a machine learning classifier can evaluate image quality of maximum intensity projection (MIP) images from F18-FDG-PET scans. A total of 400 MIP images from F18-FDG-PET with simulated decreasing acquisition time (120 s, 90 s, 60 s, 30 s and 15 s per bed-position) using block sequential regularized expectation maximization (BSREM) with a beta-value of 450 and 600 were created. A machine learning classifier was fed with 283 images rated "sufficient image quality" and 117 images rated "insufficient image quality". The classification performance of the machine learning classifier was assessed by calculating sensitivity, specificity, and area under the receiver operating characteristics curve (AUC) using reader-based classification as the target. Classification performance of the machine learning classifier was AUC 0.978 for BSREM beta 450 and 0.967 for BSREM beta 600. The algorithm showed a sensitivity of 89% and 94% and a specificity of 94% and 94% for the reconstruction BSREM 450 and 600, respectively. Automated assessment of image quality from F18-FDG-PET images using a machine learning classifier provides equivalent performance to manual assessment by experienced radiologists.


Assuntos
Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons , Redes Neurais de Computação , Algoritmos , Processamento de Imagem Assistida por Computador/métodos
9.
J Clin Med ; 12(8)2023 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-37109351

RESUMO

BACKGROUND: The resorption of magnesium-based alloy bioabsorbable screws results in the release of hydrogen gas, which can mimic infection and enter the growth plate. The screw itself and the released gas may also affect image quality. OBJECTIVE: The evaluation of magnetic resonance imaging (MRI) findings during the most active phase of screw resorption is the objective, with particular focus on the growth plate and to assess for the presence of metal-induced artifacts. MATERIAL AND METHODS: In total, 30 prospectively acquired MRIs from 17 pediatric patients with fractures treated with magnesium screws were assessed for the presence and distribution of intraosseous, extraosseous, and intra-articular gas; gas within the growth plate; osteolysis along the screw; joint effusion; bone marrow edema; periosteal reaction; soft tissue edema; and metal-induced artifacts. RESULTS: Gas locules were found in the bone and soft tissues in 100% of the examinations, intra-articular in 40%, and in 37% of unfused growth plates. Osteolysis and the periosteal reaction were present in 87%, bone marrow edema in 100%, soft tissue edema in 100%, and joint effusion in 50% of examinations. Pile-up artifacts were present in 100%, and geometric distortion in 0% of examinations. Fat suppression was not significantly impaired in any examination. CONCLUSIONS: Gas and edema in the bone and soft tissues are normal findings during the resorption of magnesium screws and should not be misinterpreted as infection. Gas can also be detected within growth plates. MRI examinations can be performed without metal artifact reduction sequences. Standard fat suppression techniques are not significantly affected.

10.
Neuroradiology ; 65(4): 729-736, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36633612

RESUMO

PURPOSE: To evaluate and compare which factors are relevant to the diagnostic decision-making and imaging workup of intracerebral hemorrhages in large, specialized European centers. METHODS: Expert neuroradiologists from ten large, specialized centers (where endovascular stroke treatment is routinely performed) in nine European countries were selected in cooperation with the European Society of Neuroradiology (ESNR). The experts were asked to describe how and when they would investigate specific causes in a patient who presented with an acute, atraumatic, intracerebral hemorrhage for two given locations: (1) basal ganglia, thalamus, pons or cerebellum; (2) lobar hemorrhage. Answers were collected, and decision trees were compared. RESULTS: Criteria that were considered relevant for decision-making reflect recommendations from current guidelines and were similar in all participating centers. CT Angiography or MR angiography was considered essential by the majority of centers regardless of other factors. Imaging in clinical practice tended to surpass guideline recommendations and was heterogeneous among different centers, e.g., in a scenario suggestive of typical hypertensive hemorrhage, recommendations ranged from no further follow-up imaging to CT angiography and MR angiography. In no case was a consensus above 60% achieved. CONCLUSION: In European clinical practices, existing guidelines for diagnostic imaging strategies in ICH evaluation are followed as a basis but in most cases, additional imaging investigation is undertaken. Significant differences in imaging workup were observed among the centers. Results suggest a high level of awareness and caution regarding potentially underlying pathology other than hypertensive disease.


Assuntos
Hemorragia Cerebral , Acidente Vascular Cerebral , Humanos , Hemorragia Cerebral/diagnóstico por imagem , Hemorragia Cerebral/patologia , Acidente Vascular Cerebral/terapia , Europa (Continente) , Tomografia Computadorizada por Raios X , Hospitais
11.
BMC Pediatr ; 22(1): 584, 2022 10 08.
Artigo em Inglês | MEDLINE | ID: mdl-36209062

RESUMO

BACKGROUND: The size of the anterior visual pathway (AVP) structures is affected by patient age and pathology. Normative data is useful when determining whether pathology is present. AVP structures do not respect the standard planes of magnetic resonance (MR) imaging. The aim of this study was to produce normative age-related and axis-corrected data of the AVP structures using multiplanar reformation (MPR) of high-resolution 3D T2-weighted fast spin echo (3D T2w FSE) images. METHODS: For each patient 32 measurements of AVP structures were obtained in 145 children (2 months - 18 years) with normal brain MR studies on high-resolution 3D T2w FSE images adjusted to the axis of each AVP structure. Descriptive statistics were calculated for different age classes and growth models were fitted to the data and assessed for their performance to create a formal statistical model that allows inference beyond the sample. RESULTS: Descriptive statistics were compiled in a reference table and prediction plots in relation to age, height, and body surface area (BSA) were obtained from the best overall performing statistical model, also taking field strength (1.5 vs. 3 T) into account. Intraclass correlation coefficient values were calculated for all variables ranging from 0.474 to 0.967, the most reliable being the transverse diameter of the globe, the maximum diameter of the retrobulbar nerve sheath, the intracranial segment of the optic nerve and the transverse diameter of the chiasm. The maximum retrobulbar diameter of the optic nerve sheath and the lateral superoinferior diameter of the chiasm showed no statistically significant change with age. CONCLUSION: Detailed charts of reference values for AVP structures as well as prediction plots in relation to age, height and BSA were established using axis-corrected measurements from the MPR of high-resolution 3D T2w FSE images. Furthermore, an Excel spreadsheet that allows users to calculate normative values for the 9 AVP structures of key interest is provided as supplementary material.


Assuntos
Imageamento Tridimensional , Vias Visuais , Criança , Humanos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Modelos Estatísticos , Valores de Referência , Vias Visuais/diagnóstico por imagem
12.
Pediatr Radiol ; 52(13): 2584-2594, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35836016

RESUMO

BACKGROUND: Exposure of the eye lens to ionizing radiation results in cataract. Several dose optimization techniques to protect the lens are available for computed tomography (CT). OBJECTIVE: The radiation dose to the eye lens, volume CT dose index (CTDIvol) and image quality of various methods of dose optimization were evaluated for pediatric head CT: automated tube current modulation (ATCM), automated tube voltage selection (ATVS), organ-based tube current modulation (OBTCM) and bismuth shielding. MATERIALS AND METHODS: An anthropomorphic phantom of a 5-year-old child was scanned with nine protocols: no dose optimization technique and then adding different dose optimization techniques alone and in combination. Dose to the eye, thyroid and breast were estimated using metal oxide semiconductor field effect transistor (MOSFET) dosimetry. CTDIvol, influence of timing of shield placement, image noise and attenuation values in 13 regions of interest of the head and subjective image quality were compared. RESULTS: The eye shield significantly reduced the eye lens dose when used alone, to a similar degree as when using all software-based techniques together. When used in combination with software-based techniques, the shield reduced the eye lens dose by up to 45% compared to the no dose optimization technique. Noise was significantly increased by the shield, most pronounced in the anterior portion of the eye. CONCLUSION: The combination of ATCM, ATVS, OBTCM and a bismuth shield, with the shield placed after acquiring the localizer image, should be considered to reduce the radiation dose to the eye lens in pediatric head CT.


Assuntos
Bismuto , Proteção Radiológica , Criança , Humanos , Pré-Escolar , Doses de Radiação , Proteção Radiológica/métodos , Cabeça/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas
13.
Insights Imaging ; 13(1): 118, 2022 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-35838922

RESUMO

BACKGROUND: Quantifying femoral and tibial torsion is crucial in the preoperative planning for derotation surgery in children and adolescents. The use of an ultra-low-dose computed tomography (CT) protocol might be possible for modern CT scanners and suitable for reliable torsion measurements even though the bones are not completely ossified. METHODS: This is a retrospective review of 77 children/adolescents (mean age 12.7 years) who underwent a lower extremity CT for torsion measurements on a 64-slice scanner. A stepwise dose reduction (70%, 50%, 30% of the original dose) was simulated. Torsion measurements were performed on all image datasets, and image noise, interrater agreement and subjective image quality were evaluated. Effective radiation dose of each original scan was estimated. As proof of concept, 24 children were scanned with an ultra-low-dose protocol, adapted from the 30% dose simulation, and the intra-class correlation coefficient (ICC) was determined. Ethics approval and informed consent were given. RESULTS: Torsion measurements at the simulated 30% dose level had equivalent interrater agreement compared to the 100% dose level (ICC ≥ 0.99 for all locations and dose levels). Image quality of almost all datasets was rated excellent, regardless of dose. The mean sum of the effective dose of the total torsion measurement was reduced by simulation from 0.460/0.490 mSv (boys/girls) at 100% dose to 0.138/0.147 mSv at 30%. The ICC of the proof-of-concept group was as good as that of the simulated 30% dose level. CONCLUSION: Pediatric torsion measurements of the lower extremities can be performed using an ultra-low-dose protocol without compromising diagnostic confidence.

14.
Eur J Radiol Open ; 9: 100431, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35765661

RESUMO

Purpose: To compare temporal evolution of imaging features of coronavirus disease 2019 (COVID-19) and influenza in computed tomography and evaluate their predictive value for distinction. Methods: In this retrospective, multicenter study 179 CT examinations of 52 COVID-19 and 44 influenza critically ill patients were included. Lung involvement, main pattern (ground glass opacity, crazy paving, consolidation) and additional lung and chest findings were evaluated by two independent observers. Additional findings and clinical data were compared patient-wise. A decision tree analysis was performed to identify imaging features with predictive value in distinguishing both entities. Results: In contrast to influenza patients, lung involvement remains high in COVID-19 patients > 14 days after the diagnosis. The predominant pattern in COVID-19 evolves from ground glass at the beginning to consolidation in later disease. In influenza there is more consolidation at the beginning and overall less ground glass opacity (p = 0.002). Decision tree analysis yielded the following: Earlier in disease course, pleural effusion is a typical feature of influenza (p = 0.007) whereas ground glass opacities indicate COVID-19 (p = 0.04). In later disease, particularly more lung involvement (p < 0.001), but also less pleural (p = 0.005) and pericardial (p = 0.003) effusion favor COVID-19 over influenza. Regardless of time point, less lung involvement (p < 0.001), tree-in-bud (p = 0.002) and pericardial effusion (p = 0.01) make influenza more likely than COVID-19. Conclusions: This study identified differences in temporal evolution of imaging features between COVID-19 and influenza. These findings may help to distinguish both diseases in critically ill patients when laboratory findings are delayed or inconclusive.

15.
Insights Imaging ; 13(1): 91, 2022 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-35551532

RESUMO

OBJECTIVES: The supraacetabular fossa (SAF) is an anatomical variant of the acetabular roof which may mimic a cartilage defect. Two different subtypes have been described: type 1 fluid-filled and type 2 cartilage-filled. The adult prevalence of SAF was reported between 10.5 and 12.6%. We aimed to determine SAF prevalence in a pediatric and young adult population and examine the potential remodeling of the subtypes over time. METHODS: A retrospective search of the institutional database for hip MRI of participants aged 4-25 years was carried out between 2010 and 2020. A total of 401 eligible MRIs of 323 participants were analyzed by two readers. The documented features were: existence of SAF, definition of subtype and measurements of the SAF in three dimensions. Logistic regression models were calculated to estimate the influence of age on the presence of SAF. RESULTS: Out of 323, 115 (35,6%) participants demonstrated a supraacetabular fossa. 63 (19.5%) participants presented subtype 1 and 51 (15.8%) type 2; one participant had both. The predicted probability for SAF increases until the age of 14, beyond 14 years, the combined predicted probability for both subtypes decreased again. In contrast to SAF type 1, SAF type 2 was more prevalent with older age. The size of the SAF decreased with aging. CONCLUSION: The supraacetabular fossa is most frequent in adolescents. With higher age, the prevalence and the size of the SAF decreased. This data supports the theory that the SAF is a developmental variant.

16.
Pediatr Radiol ; 52(12): 2368-2376, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35606529

RESUMO

BACKGROUND: Resorption of magnesium-based alloy bioabsorbable screws produces hydrogen gas, which can be mistaken as a sign of infection and may affect the physis or fixed bone fragment. OBJECTIVE: We evaluated the temporal and spatial occurrence of gas and the occurrence of a breakage of the fixed bone fragment or screw following magnesium screw fixation. MATERIALS AND METHODS: Radiographs of paediatric patients treated with magnesium screws were retrospectively reviewed. Temporal occurrence and distribution of gas in the bone, the physis and soft tissues, breakage of the screw or fixed bone fragment and joint effusion were assessed. RESULTS: One hundred and three radiographs in 35 paediatric patients were reviewed (mean age: 10.6 years). Follow-up ranged from 1 to 730 days. Gas in the bone increases up to week 5, remains constant up to week 16 and then decreases. Gas in soft tissues, intra-articular gas and joint effusions gradually reduce over time. In 1/23 (4.3%) patients with an open physis, gas intrusion into the physis occurred. Breakage of the bone fragment fixated by the screw was observed in 4/35 (11.4%) patients within the first 6 weeks. Screw breakage was observed in 16/35 (45.7%) patients, with a median time to first detection of 300 days. CONCLUSION: Gas bubbles in bone and soft tissue are normal findings in the context of screw resorption and should not be confused with soft-tissue infection or osteomyelitis. Gas is rarely visible in the physis. Breakage of the fixed bone fragment and/or screw can occur.


Assuntos
Fraturas Ósseas , Magnésio , Humanos , Criança , Implantes Absorvíveis , Estudos Retrospectivos , Parafusos Ósseos , Ligas , Fraturas Ósseas/etiologia
17.
J Magn Reson Imaging ; 56(5): 1571-1579, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35106870

RESUMO

BACKGROUND: Diagnosis of osteomyelitis by imaging can be challenging. The feasibility of diffusion-weighted imaging (DWI) as ancillary sequence was evaluated in this study. PURPOSE: To evaluate DWI for differentiation between osteomyelitis, bone marrow edema, and healthy bone on forefoot magnetic resonance imaging (MRI). STUDY TYPE: Prospective. SUBJECTS: A total of 60 consecutive patients undergoing forefoot MRI divided into three study groups (20 subjects each): osteomyelitis, bone marrow edema, and healthy bone. FIELD STRENGTH/SEQUENCE: A 1.5T and 3T MRI scanners; readout-segmented multishot echo planar DWI. ASSESSMENT: Two independent radiologists measured apparent diffusion coefficient (ADC) values within abnormal or healthy bone. STATISTICAL TESTS: ADC values were compared between groups (pairwise t-test with Bonferroni-Holm correction for multiple testing). Intraclass correlation coefficient (ICC) was calculated to assess inter-reader agreement. Threshold ADC values were determined as the cutoffs that maximized the sum of sensitivity and specificity. Receiver operating characteristic (ROC) analysis was performed with statistical threshold of P < 0.05. RESULTS: Inter-reader agreement was 0.92 in the healthy bone group and 0.78 in both the edema and osteomyelitis groups. Average ADC values were significantly different between groups: 1432 ± 222 × 10-6  mm2 /sec (osteomyelitis), 1071 ± 196 × 10-6  mm2 /sec (bone marrow edema), and 277 ± 89 × 10-6  mm2 /sec (healthy bone). A threshold ADC value of 534 × 10-6  mm2 /sec distinguishes between healthy and abnormal bone with specificity and sensitivity of 100% each. For distinction between osteomyelitis and bone marrow edema, two cutoff values were determined: a 95%-specificity cutoff indicating osteomyelitis (>1320 × 10-6  mm2 /sec) and a 95%-sensitivity cutoff indicating bone marrow edema (<1155 × 10-6  mm2 /sec). Diagnostic accuracy of 95% was achieved for 73% (29/40) of the subjects. DATA CONCLUSION: DWI with ADC maps distinguishes between healthy and abnormal bone on forefoot MRI. Calculated cutoff values allow confirmation or exclusion of osteomyelitis in a high proportion of subjects. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 2.


Assuntos
Doenças da Medula Óssea , Osteomielite , Medula Óssea/diagnóstico por imagem , Medula Óssea/patologia , Doenças da Medula Óssea/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Edema/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Osteomielite/diagnóstico por imagem , Estudos Prospectivos , Sensibilidade e Especificidade
18.
Skeletal Radiol ; 51(3): 573-579, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34255126

RESUMO

OBJECTIVE: Short tau or short TI inversion recovery (STIR) MRI sequences are considered a robust fat suppression technique. However, STIR also suppresses signals from other tissues with similar T1 relaxation times. This study investigates the in vivo effect of intravenous gadolinium-based T1-shortening contrast agent on STIR signal. MATERIALS AND METHODS: Institutional board approval and informed consent was obtained. MRI examinations (1.5-T or 3-T) of 31 prospectively included patients were analyzed by two readers. Signal intensity of degenerative bone marrow edema-like signal at the Lisfranc joint on precontrast STIR images and on STIR images acquired after intravenous contrast agent administration (gadoteric acid, gadolinium: 0.5 mmol/ml, 15 ml) was measured. The medial cuneiform bone without observable bone marrow edema-like signal was considered a healthy tissue and served as a reference. Relative changes in signal intensity between precontrast and postcontrast images were calculated for the two tissues. Wilcoxon signed-rank test served for statistical analyses. RESULTS: In bone marrow edema-like signal, both readers observed a median signal change of -35% (interquartile range (IQR) 24) and -34% (IQR 21), respectively, on postcontrast STIR images compared to precontrast STIR. In healthy tissue, the signal remained constant on postcontrast STIR images (median change -2%, IQR 15, and 0%, IQR 17) respectively. For both readers, postcontrast signal change in bone marrow edema-like signal differed from that in healthy tissue (p < 0.001). CONCLUSION: Intravenous gadolinium-based contrast agent causes a significant reduction of signal intensity in bone marrow edema-like signal on routine STIR images. Thus, pathological MRI findings may be obscured.


Assuntos
Doenças da Medula Óssea , Meios de Contraste , Medula Óssea/diagnóstico por imagem , Doenças da Medula Óssea/induzido quimicamente , Doenças da Medula Óssea/diagnóstico por imagem , Edema/induzido quimicamente , Edema/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética
19.
BMC Pediatr ; 21(1): 276, 2021 06 11.
Artigo em Inglês | MEDLINE | ID: mdl-34116649

RESUMO

BACKGROUND: Organ size is influenced by a number of factors. Age, height, weight, and ethnicity are known influencing factors. Pediatric populations have changed over time, puberty beginning earlier resulting in a changing growth pattern of their organs. Hence, contemporary charts using local data are considered the most appropriate for a given population. Sonographic charts for liver size for a predominantly Caucasian population are limited, which has implications for clinical practice. The aim of this study was to define a contemporary normative range of liver and spleen sizes for a healthy, predominantly Caucasian population and for all pediatric age groups (0-18 years) and to investigate whether there is a size difference between genders and ethnicities. METHODS: Retrospective study including children with normal sonographic findings and no evidence of liver or splenic disease clinically. Craniocaudal and anteroposterior dimensions are measured for the right and left lobe of the liver, and craniocaudal dimension for the spleen. Relationship of the liver and spleen dimensions with age, body length, body surface area, weight, and gender were investigated. Charts of normal values were established. Values were compared to studies involving other ethnicities and to one study carried out in 1983 involving the same ethnicity. RESULTS: Seven hundred thirty-six children (371 boys, 365 girls) aged 1 day - 18.4 years were included. From the second year of life, the craniocaudal dimension of the right lobe of the liver is 1-2 cm larger in the Central European population compared with non-Caucasian populations at a given age. Liver size of Central European children in 2020 is greater compared to a similar population almost 40 years ago. The craniocaudal dimension of the spleen of Central European, US-American and Turkish children is similar. The difference between genders is statistically significant for both the liver and the spleen, being larger in boys. CONCLUSION: Contemporary and ethnically appropriate reference charts for liver and spleen measurements should be used, especially for liver size. The effect of ethnicity is reduced if patient height rather than age is referenced.


Assuntos
Fígado , Baço , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Fígado/diagnóstico por imagem , Masculino , Tamanho do Órgão , Valores de Referência , Estudos Retrospectivos , Baço/diagnóstico por imagem , Ultrassonografia
20.
BJR Case Rep ; 7(2): 20200077, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-33841897

RESUMO

Combined hamartoma of the retina and retinal pigment epithelium is a rare benign ocular tumour in children, composed of glial cells, vascular tissue, and sheets of pigmented epithelial cells. Although generally thought to be congenital, acquired cases are known to exist. It usually presents with reduced visual acuity and/or strabismus and it can be associated with several syndromes, including Neurofibromatosis Type 2. There is no consensus on the management of combined hamartoma of the retina and retinal pigment epithelium. We present a case, including MRI features, of a 4,5-years-old girl with a combined hamartoma of the retina and retinal pigment epithelium.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...